| Voltage
range (max. Vrms) |
48-660 |
| Peak
voltage - t = 1 min (V) |
1000 |
| Max.
current (A) |
35 |
| Off-state
leakage at V max and 25 oC (mA) |
8 |
| Max.
current surge 1
Cycle (Apeak) |
750 |
| 1
sec (Apeak) |
145 |
| On-state
voltage drop at I max (Vpeak) |
1.6 |
| I2t
- t = 10 ms(A2s) |
1260 |
| Static
dv/dt (V/µs) |
500 |
| Supply
frequency range (Hz) |
47
to 63 |
| Thermal
resistance Junction / ambient air |
3.78
2 / W |
| |
|
| Control
input specifications |
|
| Input
voltage (V) |
4
to 32 |
| Drop-out
voltage |
1
V |
| Max.
input current (mA) |
10 |
| Response
time
on opening |
0.5 |
| (max.
period)
on closing |
0.5 |
| |
|
| DC
power supply / Alarm output |
|
| Supply
voltage (in relation to the relay - terminal) |
4
to 32 |
| Current |
15
to 45 mA |
| Voltage
: alarm output |
4
to 32 |
| Current
: alarm output |
60
mA |
| Voltage
: overheat output |
4
to 32 V |
| Current
: overhead output |
60
mA |
| |
|
| Characteristics |
|
| Temperature Operation |
-20
to 80 oC |
| limits Stored |
-40
to 100 oC |
| Input
to output insulation voltage |
4000
Vrms |
| Breakdown
voltage |
2500
Vrms |
| input/output
capacitance |
8
pF |